Understanding the physiological effects of wearing enhanced personal protective equipment while providing patient care

Authors

  • Julie Bulson, DNP, MPA, RN, NE-BC
  • Kenneth Shawl, BBA, RRT, NHDP-BC

DOI:

https://doi.org/10.5055/jem.2019.0444

Keywords:

personal protective equipment, PPE, vital signs, physiological, temperature, emergency, preparedness, disaster, response

Abstract

Purpose: There is a lack of information regarding the physiological effects of healthcare workers performing patient care while wearing enhanced personal protective equipment (PPE). This study aimed to provide foundational data necessary to maintain the health and safety of healthcare workers while performing tasks wearing enhanced PPE related to patient care in a biocontainment unit.

Design and method: This study is a descriptive study evaluating the physiological effects of conducting patient care while wearing enhanced PPE. Participant vital signs (blood pressure, body temperature, and oxygen saturation) were monitored pre-donning, throughout the transport, and post-doffing.

Results: There is no statistically significant difference in the physiological measurements of any of the participants. The results consisted of: blood pressure (systolic p = 0.0659; diastolic p = 0.94345); oxygen saturation (p = 0.6233); and orally derived body temperature (p = 0.1093). Physical balance was subjectively measured by both the participant and the trained observer during the donning and doffing process. Results show no visible difference in balance between the donning period and the doffing period.

Conclusion: This study demonstrated there were no physiological changes to the healthcare workers in this study performing patient care activities during patient transport and in a biocontainment unit while wearing the provided enhanced PPE. However, limitations of this study include: (1) it was conducted at one location within the Midwest; (2) with a small number of participants; and (3) only the enhanced ensemble of PPE was worn during testing. Therefore, the results may not be generalizable to other locations or levels of PPE.

Clinical relevance: This study will help to guide assessment standards for healthcare workers providing care while wearing enhanced level PPE.

Author Biographies

Julie Bulson, DNP, MPA, RN, NE-BC

Director, Emergency Preparedness, Spectrum Health, Grand Rapids, Michigan

Kenneth Shawl, BBA, RRT, NHDP-BC

Emergency Preparedness Specialist - Hospital Emergency Response Team (HERT) and Special Pathogens Program Team Lead, Spectrum Health, Grand Rapids, Michigan

References

World Health Organization: Disease outbreaks by year, 2019. Available at https://www.who.int/csr/don/archive/year/en/. Accessed February 7, 2019.

CDC: Guidance on Personal Protective Equipment (PPE) | Public Health Planners | Ebola (Ebola Virus Disease). 2018. Available at https://www.cdc.gov/vhf/ebola/healthcare-us/ppe/guidance.html. Accessed February 5, 2019.

Tomas ME, Kundrapu S, Thota P, et al.: Contamination of health care personnel during removal of personal protective equipment. JAMA Intern Med. 2015; 175(12): 1904-1910. doi:10.1001/jamainternmed.2015.4535.

DeMaio M, Onate J, Swain D, et al.: Physical Performance Decrements in Military Personnel Wearing Personal Protective Equipment (PPE). NATO Military Operations. Portsmouth, VA: Department of Orthopaedic Surgery, Naval Medical Center, 2009: P2-1-P2-6. Available at http://www.dtic.mil/dtic/tr/fulltext/u2/a567881.pdf. Accessed October 15, 2018.

Indutex: SprayGuard Coveralls Data Sheet. 2008. Available at http://indutexusa.com/uploads/3/4/7/5/34758205/spray_guard_product_data_sheet.pdf. Accessed February 6, 2019.

Indutex SPA: Intertek Test Report. New York, 2015: 1-3. Available at http://www.evolvetechcorp.com/Image/G102210076%20Indutex%201670%20%201671%20Report.pdf. Accessed February 6, 2019.

UNICEF: Ebola Virus Disease: Personal Protective Equipment, UNICEF Specifications. UNICEF Supply Division, 2015: 1-10. Available at https://www.unicef.org/supply/files/UNICEF_Ebola_Low-Resource_Settings_PPE_Specifications_Note.pdf. Accessed February 4, 2019.

Blacker SD, Carter JM, Wilkinson DM, et al.: Physiological responses of police officers during job simulations wearing chemical, biological, radiological and nuclear personal protective equipment. Ergonomics. 2012; 56(1): 137-147. doi:10.1080/00140139.2012.734335.

Buller MJ, Tharion WJ, Karis AJ, et al.: Demonstration of Real-Time Physiological Status Monitoring of Encapsulated 1st Civil Support Team—Weapons of Mass Destruction (CSTWMD) Personnel. Natick, MA: US Army Research Institute of Environmental Medicine, 2007.

Buller M, Tharion WJ, Duhamel CM, et al.: Real-time core body temperature estimation from heart rate for first responders wearing different levels of personal protective equipment. Ergonomics. 2015; 58(11): 1830-1841. doi:10.1808/00140139.2015.1036792.

Petruzzello SJ, Gapin JI, Snook E, et al.: Perceptual and physiological heat strain: Examination in firefighters in laboratory and field-based studies. Ergonomics. 2009; 52(6): 747-754.

Published

12/01/2019

How to Cite

Bulson, DNP, MPA, RN, NE-BC, J., and K. Shawl, BBA, RRT, NHDP-BC. “Understanding the Physiological Effects of Wearing Enhanced Personal Protective Equipment While Providing Patient Care”. Journal of Emergency Management, vol. 17, no. 6, Dec. 2019, pp. 517-21, doi:10.5055/jem.2019.0444.